Free
Education  |   April 2016
Bedside Ultrasound: A Tool for Assessment of IV Functionality
Author Notes
  • From the Department of Anesthesiology and Critical Care Medicine, The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania (A.C.A., D.H.J.); Division of Cardiothoracic Anesthesiology, The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania (A.C.A.); and the Divisions of Cardiothoracic Anesthesiology (A.C.A.) and General Anesthesiology (D.H.J.), Perelman School of Medicine, The University of Pennsylvania, Philadelphia, Pennsylvania.
  • Supplemental Digital Content is available for this article. Direct URL citations appear in the printed text and are available in both the HTML and PDF versions of this article. Links to the digital files are provided in the HTML text of this article on the Journal’s Web site (www.anesthesiology.org).
    Supplemental Digital Content is available for this article. Direct URL citations appear in the printed text and are available in both the HTML and PDF versions of this article. Links to the digital files are provided in the HTML text of this article on the Journal’s Web site (www.anesthesiology.org).×
  • All authors contributed substantially to the concepts discussed in the manuscript and have approved the final manuscript.
    All authors contributed substantially to the concepts discussed in the manuscript and have approved the final manuscript.×
  • Address correspondence to Dr. Adler: adlera@email.chop.edu
Article Information
Education / Images in Anesthesiology / Cardiovascular Anesthesia / Pain Medicine / Patient Safety / Pediatric Anesthesia / Radiological and Other Imaging / Technology / Equipment / Monitoring / Quality Improvement
Education   |   April 2016
Bedside Ultrasound: A Tool for Assessment of IV Functionality
Anesthesiology 4 2016, Vol.124, 959. doi:10.1097/ALN.0000000000000884
Anesthesiology 4 2016, Vol.124, 959. doi:10.1097/ALN.0000000000000884
Abstract

Supplemental Digital Content is available in the text.

BEDSIDE ultrasound has numerous applications for the anesthesiologist in the perioperative setting.1  Frequently, especially in the pediatric population, patients arrive with small IV catheters that either do not flush or flush with considerable discomfort causing concern for infiltration. Patients with excessive subcutaneous fat or edema can mask IV infiltrations until considerable volume has extravasated. IV catheters that are properly intravenous often elicit pain on injection.
The subcostal four-chamber view or inferior vena cava view allows for identification of turbulent flow within the right heart after a small bolus of saline (5 to 10 ml). The figure shows the subcostal and inferior vena cava views presaline bolus (figs. A and B) and post-saline bolus (figs. B and E; yellow star; Supplemental Digital Content 1, video, http://links.lww.com/ALN/B224). The figure (figs. C and F) illustrates the correct placement of the probe for optimal image acquisition. Imaging should be done with a phased array (cardiac) probe, which is available for most portable ultrasound machines. In obese patients or parturients, the scanning depth should be increased. Alternatively, the parasternal short- and long-axis views may be substituted to allow for qualitative assessment of fluid entry. Turbulence should be assessed with 2D ultrasound, and color Doppler may be applied especially when scanning at larger depths in adults.
The importance of identifying IV infiltration before induction of anesthesia with potentially irritant medications cannot be overstated. IV infiltration is a significant cause of morbidity according to the closed claims reports of the American Society for Anesthesiologists.2  Despite this, best practice guidelines for intraoperative IV assessment are lacking.3  This simple technique using bedside ultrasound provides some reassurance for the anesthesia provider as to the location of the IV catheter. With the availability of ultrasound in anesthesia practice, this rapid assessment tool may provide an increased measure of patient safety.
Competing Interests
The authors declare no competing interests.
References
Barbara, DW Images in anesthesiology: Bedside lung ultrasonography: A tool for rapid assessment of pneumothorax.. Anesthesiology. (2015). 122 921 [Article] [PubMed]
Bhananker, SM, Liau, DW, Kooner, PK, Posner, KL, Caplan, RA, Domino, KB Liability related to peripheral venous and arterial catheterization: A closed claims analysis.. Anesth Analg. (2009). 109 124–9 [Article] [PubMed]
Ball, RD, Henao, JP, Ibinson, JW, Metro, DG Peripheral intravenous catheter infiltration: Anesthesia providers do not adhere to their own ideas of best practice.. J Clin Anesth. (2013). 25 115–20 [Article] [PubMed]