PREVIOUS experimental and clinical studies have established that inhaled nitric oxide (NO) is a selective pulmonary vasodilator in pulmonary hypertension. [1] It has been shown to be beneficial in hypoxemic patients with acute respiratory distress syndrome (ARDS) by reducing pulmonary arterial pressure and improving arterial oxygenation. [2] Inhaled NO, like endogenous NO, relaxes the smooth muscles in arteries and veins by activating soluble guanylate cyclase and increasing cyclic guanosine 3'-5'-monophosphate. Increased pulmonary artery pressure in ARDS, which results from the combined effects of hypoxic vasoconstriction, the release of mediators, and microthrombosis of pulmonary circulation, [3,4] represents an increase in the outflow pressure load on the right ventricle (RV). This can decrease right ventricle ejection fraction (RVEF) and increase RV volume, [5] causing RV dysfunction. [6] 
Administration of catecholamines increases systemic blood pressure and is used in the critical care setting to obtain adequate tissue perfusion pressure. [7] Recently, the use of norepinephrine has been reconsidered in patients with septic shock and a persistent low systemic vascular resistance index. [7,8] Acute dysfunction of the RV occurs frequently with septic shock and may be a major limiting factor of survival. [9,10] The lack of deleterious effect of norepinephrine on RV function has been shown in patients in septic shock. [11] However, an elevated pulmonary vascular resistance index induced by norepinephrine could be deleterious in patients with ARDS who have hypoxia-related pulmonary vasoconstriction. Recent research has suggested that only 40% of ARDS patients with associated septic shock responded to inhaled NO. [12] This would appear to conflict with the results of a study by Mourgeon et al., [13] who showed that the increase in arterial oxygenation observed in ARDS patients was more marked when ARDS was associated with septic shock treated by norepinephrine. Therefore, our objectives in this prospective study were (1) to compare the dose-response profile of inhaled NO in ARDS patients with sepsis who were receiving norepinephrine with those of patients who were not receiving norepinephrine, and (2) to examine the effects of norepinephrine and inhaled NO on RV function.
Materials and Methods
Patients
During a 15-month period, 27 patients with sepsis (group 1: 15 patients not receiving norepinephrine; group 2: 12 patients receiving norepinephrine) with ARDS diagnosed on or after admission to the medicosurgical intensive care unit of Sainte-Marguerite University Hospital in Marseille, France, were prospectively investigated early in the course of their ARDS (<4 days) after written informed consent was obtained from each patient's next of kin. The study was approved by the Comite Consultatif de Protection des Personnes dans la Recherche Biomedicale of Marseille and supported by l'Assistance Publique Hopitaux de Marseille and the French Ministry of Health (Project Hospitalier de Recherche Clinique, 1994). We used the definition of ARDS recommended by the American-European Consensus Conference. [14] Septic shock, sepsis, and the systemic inflammatory response syndrome were defined according to the criteria of the American College of Chest Physicians/Society of Critical Care Medicine consensus conference. [15] In the current study, patients with septic shock received norepinephrine when systolic arterial pressure was < 90-100 mmHg despite fluid expansion. The goal of fluid expansion when patients received norepinephrine was to obtain a pulmonary artery occlusion pressure between 12 and 18 mmHg at baseline (before administration of inhaled NO). Mechanical ventilation preceding the study had lasted 6 +/− 4 days. All patients were sedated and paralyzed with a continuous infusion of sufentanil, midazolam, and vecuronium bromide, and the lungs were ventilated using conventional volume-controlled mechanical ventilation (Puritan Bennett 7200 series, Carlsbad, CA). For each patient, tidal volume, respiratory rate, and fractional concentration of oxygen in inspired gas (FIO(2)) were adjusted to maintain the minute ventilation constant throughout the study. To detect changes in FIO(2) induced by inhalation of NO, FiO(2) was monitored continuously using an oxygen analyzer (NOX 4000; Seres, Aix-en-Provence, France). All patients had a radial artery catheter (Seldicath, Plastimed, Saint Leu la Foret, France) and a pulmonary artery catheter equipped with a fast-response thermistor (model 93 A-434H-7.5F; Baxter Healthcare Corp., Irvine, CA) that was inserted percutaneously through the right jugular or the left axillary vein and positioned so that the distal port was in the pulmonary artery and the proximal port was in the right atrium, just above the tricuspid valve.
Measurements
Systolic arterial pressure, diastolic arterial pressure, systolic pulmonary arterial pressure, diastolic pulmonary arterial pressure, pulmonary artery occlusion pressure, and right atrial pressure were measured at end-expiration. The supine zero reference level was the mid-axilla. Right ventricular end-diastolic and end-systolic volume indices were calculated from the RVEF and the stroke volume. Right ventricular ejection fraction and cardiac output were measured by thermodilution using three to five boluses of 10-ml glucose solution between 6 [degree sign]C and 10 [degree sign]C, injected via a closed system (Co-set; Baxter Healthcare Corp.) at end-inspiration to improve the reproducibility of the measurement and also to minimize the influence of changes in intrathoracic pressure on RVEF. Injection temperature was measured by a thermistor located at the proximal port of the right atrial lumen. The mean of three measurements is reported. Right ventricular ejection fraction was evaluated with an algorithm based on an exponential curve analysis using a computer (Edwards Cardiac Output computer REF-1; Baxter Healthcare Corp.), as previously described and validated. [16] The use of this algorithm reduces the variability of RVEF measurement to <8% in the absence of atrial fibrillation. [17] Patients with cardiac dysrhythmias were not included. In all but two patients, two-dimensional echocardiography was performed at the bedside. Tricuspid regurgitation was ruled out using Doppler echocardiography. Cardiac index, oxygen delivery index, oxygen consumption index, oxygen extraction ratio, right and left ventricular stroke work indices, venous admixture (QVA/Q(T)), systemic vascular resistances and pulmonary vascular resistances (PVRI) were calculated using standard formulas. Systemic and pulmonary arterial blood samples were withdrawn simultaneously within 3 min of the measurement of cardiac output. Arterial pH, oxygen tension in arterial blood (PaO(2)), partial oxygen pressure in mixed venous blood, and carbon dioxide tension in arterial blood were measured using a blood gas analyzer (278-blood gas system; Ciba Corning, Medfield, MA). Hemoglobin concentration, arterial and mixed venous oxygen saturations, and methemoglobin levels were measured using a calibrated hemoximeter (270-CO-oxymeter; Ciba Corning). The following respiratory parameters were collected: exhaled tidal volume, peak inspiratory pressure, mean inspiratory pressure, and respiratory rate. Respiratory dynamic compliance was calculated as [peak inspiratory pressure - positive end-expiratory pressure]/tidal volume. Volume-controlled mechanical ventilation settings (except adjustments to maintain constant minute ventilation) and vasoactive agents and fluid administration rates remained constant throughout the study.
Nitric Oxide Administration
Nitric oxide was released from a tank containing NO in nitrogen at a concentration of 450 parts per million (ppm; Air Liquide, Meudon, France) and was delivered continuously within the inspiratory limb of the ventilator just after the Cascade II humidifier via a flowmeter delivering flows within a range of 1-999 ml/min (Air Liquide). Intratracheal gas was sampled using continuous aspiration through the endotracheal tube, permitting inspiratory, expiratory, and mean concentrations of NO and NO2continuous determination using a chemoluminescence apparatus (NOX 4000, Seres). The flowmeter was set to reach the desired inspiratory tracheal concentration.
Protocol
The study lasted approximately 6 h for each patient. Ventilator settings were not modified throughout the study period. The protocol consisted of seven consecutive phases for the first group (ARDS patients not receiving norepinephrine) and eight consecutive phases for the second group (ARDS patients receiving norepinephrine). For the second group, measurements were performed just before norepinephrine was introduced. Subsequent measurements were performed for the two groups. Baseline measurements were made after 1 h of steady-state conventional mechanical ventilation. After these baseline measurements were taken, NO was administered at increasing inspiratory concentrations of 0.5, 2, 5, 10, and 20 ppm. Each concentration was given for 30 min. In the two groups, a second baseline was obtained 30 min after NO was discontinued.
Statistical Methods
Data are expressed as mean +/− SD. Statistical calculations were performed using the SPSS 6.1 package (Chicago, IL). Significant differences were analyzed by parametric (general factorial analysis of variance) or nonparametric (Friedman multiple comparison test) tests when required. The Mann-Whitney U test was used to assess differences between groups for a given concentration of inhaled NO. For intragroup changes, the Friedman test or Dunnett's t test for multiple comparisons were applied to compare the various time points with control values. When a correlation was calculated, Pearson's coefficient of correlations was used. When distribution was not normal, Spearman's rank correlation was used. A probability value < 0.05 indicated significance.
Results
Patients
Among the 27 patients enrolled in the study (15 men, 12 women; mean age, 51.1 +/− 17.1 yr), 7 were admitted to the intensive care unit after multiple trauma, 6 were admitted with postoperative complications after major surgery, and 14 were admitted for an acute medical illness (Table 1). On admission, the mean SAPS II score was 45.5 +/− 18.8 and the mean APACHE III score was 81.2 +/− 32.0. Eight of the 15 patients included in group 1 had sepsis, [15] whereas the remaining seven patients were considered as having a systemic inflammatory response syndrome [15] at the time of enrollment in the study. A source of infection was found in all seven of these patients during the 48-h period after the study. All the patients included in group 2 had septic shock when they were enrolled in the study. The severity of ARDS was assessed by a lung injury score >2.5 in all patients (mean, 3.1 +/− 0.3). The mortality rate for the 27 patients was 52%(group 1, 40%; group 2, 67%; difference not significant). On inclusion, peak inspiratory airway pressure was 33.1 +/− 6.0 cmH2O and the mean airway pressure was 19.9 +/− 4.0 cmH2O for all 27 patients. Mean dynamic compliance was 25.0 +/− 7.9 ml/cmH2O. When blood gases at baseline were considered, the mean PaO(2)/FIO(2) was 103 +/− 34 mmHg, and mean carbon dioxide tension in arterial blood was 42.4 +/− 8.5 mmHg. The mean positive end-expiratory pressure was 11.3 +/− 1.8 cmH2O with a FIO(2) > 0.70 in 16 of these 27 patients. Mean tidal volume was 511 +/− 92 ml, and the inspiration: expiration ratio was > 1:2 in all but three patients. Only six patients included in this study received dobutamine (7-17 [micro sign]g [middle dot] kg-1[middle dot] min-1) throughout the study. The mean dose of norepinephrine required to maintain a systolic arterial pressure > 100 mmHg was 1.0 +/− 0.7 [micro sign]g [middle dot] kg-1[middle dot] min-1(0.2-2.1 [micro sign]g [middle dot] kg-1[middle dot] min-1). No modification of the infusion rate of dobutamine and norepinephrine and no fluid expansion were undertaken during the study period. Inspiratory airway pressures (peak inspiratory pressure, mean inspiratory pressure), tidal volume, and respiratory dynamic compliance were unchanged throughout the study (data not shown). The methemoglobin concentration when inhaling 20 ppm NO (0.4%+/− 0.3%) was not different from the initial baseline concentration (0.2%+/− 0.1%).
Table 1. Characteristics of the Population
Image not available
Table 1. Characteristics of the Population
×
Effects of Norepinephrine on Hemodynamic and Gas Exchange
The administration of norepinephrine to the 12 patients included in group 2 (before the introduction of NO) did not induce any modification of gas exchange (Table 2). From a hemodynamic perspective, norepinephrine induced a significant increase in mean arterial pressure, systemic vascular resistances, and mean pulmonary arterial pressure (MPAP). Nevertheless, RVEF and RV volumes did not vary after norepinephrine was introduced.
Table 2. Hemodynamic and Respiratory Changes Induced by Norepinephrine
Image not available
Table 2. Hemodynamic and Respiratory Changes Induced by Norepinephrine
×
Dose-Response Effects of Nitric Oxide on Gas Exchange According to the Presence or Absence of Norepinephrine
(Table 3) Using a nonparametric test (Friedman test) made it possible to observe an increase in PaO(2):FIO(2) ratio for the two groups. No significant difference (using the Mann-Whitney U test) was observed between the two groups for each concentration of inhaled NO studied separately (Figure 1). Logarithmic transformation of the data led to normally distributed values of PaO(2):FIO(2). Therefore we performed a two-way analysis of variance that did not show any difference between the two groups.
Table 3. Dose-Response Effects of Nitric Oxide on Gas Exchange
Image not available
Table 3. Dose-Response Effects of Nitric Oxide on Gas Exchange
×
Figure 1. Dose-response analysis of inhaled nitric oxide in patients with (group 2: 12 patients; open bars) and without (group 1: 15 patients; hatched bars) norepinephrine (NE). For the median ratio of oxygen pressure in arterial blood to the fractional concentration of oxygen in inspired gas (25, 50, and 75 percentiles), the largest and smallest values that are not outliers are reported. Outliers (cases with values between 1.5 and 3 box-lengths from the upper or lower edge of the box) are presented as open circles. Extremes (cases with values more than 3 box-lengths from the upper or lower edge of the box) are represented by a cross.
Figure 1. Dose-response analysis of inhaled nitric oxide in patients with (group 2: 12 patients; open bars) and without (group 1: 15 patients; hatched bars) norepinephrine (NE). For the median ratio of oxygen pressure in arterial blood to the fractional concentration of oxygen in inspired gas (25, 50, and 75 percentiles), the largest and smallest values that are not outliers are reported. Outliers (cases with values between 1.5 and 3 box-lengths from the upper or lower edge of the box) are presented as open circles. Extremes (cases with values more than 3 box-lengths from the upper or lower edge of the box) are represented by a cross.
Figure 1. Dose-response analysis of inhaled nitric oxide in patients with (group 2: 12 patients; open bars) and without (group 1: 15 patients; hatched bars) norepinephrine (NE). For the median ratio of oxygen pressure in arterial blood to the fractional concentration of oxygen in inspired gas (25, 50, and 75 percentiles), the largest and smallest values that are not outliers are reported. Outliers (cases with values between 1.5 and 3 box-lengths from the upper or lower edge of the box) are presented as open circles. Extremes (cases with values more than 3 box-lengths from the upper or lower edge of the box) are represented by a cross.
×
No significant relation could be identified between NO-induced changes of the PaO(2):FIO(2) ratio and the baseline PaO(2):FI (O)(2) ratio.
A reduction in carbon dioxide tension in arterial blood was observed for the two groups, whereas minute ventilation remained constant throughout the study.
Dose-Response Effects of Nitric Oxide on Circulatory Parameters According to the Presence or Absence of Norepinephrine
(Table 4) A dose-dependent decrease of MPAP was observed in the two groups (Figure 2). This effect was more pronounced in patients receiving norepinephrine (P < 0.0001 by analysis of variance). At baseline (and for each dose of inhaled NO administered), MPAP was higher in the latter patients (P < 0.0001 by analysis of variance). Although RVEF was lower at baseline (P < 0.0001 by analysis of variance) in patients receiving norepinephrine, a greater increase in this parameter was observed when these patients received NO compared with the patients who did not receive norepinephrine (P < 0.0001 by analysis of variance). However, these changes in RVEF are probably of limited clinical value.
Table 4. Dose-Response Effects of Nitric Oxide on Circulatory Parameters
Image not available
Table 4. Dose-Response Effects of Nitric Oxide on Circulatory Parameters
×
Figure 2. The effect of nitric oxide on mean pulmonary arterial pressure (mean +/− SD) in patients receiving norepinephrine (n = 12; closed symbols) and in those who did not receive norepinephrine (n = 15; open symbols).
Figure 2. The effect of nitric oxide on mean pulmonary arterial pressure (mean +/− SD) in patients receiving norepinephrine (n = 12; closed symbols) and in those who did not receive norepinephrine (n = 15; open symbols).
Figure 2. The effect of nitric oxide on mean pulmonary arterial pressure (mean +/− SD) in patients receiving norepinephrine (n = 12; closed symbols) and in those who did not receive norepinephrine (n = 15; open symbols).
×
No significant relation could be identified between NO-induced changes of the PaO(2):FIO(2) ratio and the NO-induced variation in MPAP or PVRI. No significant relation was found between the maximal change of MPAP during NO inhalation and the baseline value of MPAP. A correlation was noted between the maximal decrease of MPAP and the maximal increase in RVEF (r = 0.43, P < 0.05).
Dose-Response Effects of Nitric Oxide on Derived Factors According to the Presence or Absence of Norepinephrine
(Table 5) Although PVRI significantly decreased in the two groups, the decrease in PVRI induced by inhaled NO was more marked in patients who received norepinephrine than in patients who did not receive norepinephrine (P < 0.0001 by analysis of variance). The maximal change of PVRI during NO inhalation correlated with baseline PVRI value in both groups (r =-0.80, P < 0.0001 in group 1; r =-0.79, P < 0.002 in group 2). The reduction in RV stroke work index was more pronounced in group 2 than in group 1 (P < 0.0001 by analysis of variance).
Table 5. Dose-Response Effects of Nitric Oxide on Derived Factors
Image not available
Table 5. Dose-Response Effects of Nitric Oxide on Derived Factors
×
Stroke volume, left ventricular stroke work index, oxygen consumption index, oxygen delivery index, and oxygen extraction ratio remained unchanged throughout the study period (data not shown).
Discussion
Acute respiratory distress syndrome is accompanied by acute pulmonary hypertension and, sometimes, acute RV dysfunction. Attempts to reduce pulmonary hypertension by administering an intravenous vasodilator are hazardous in this situation because systemic vasodilation can reduce systemic blood pressure and perfusion of the RV, leading to acute heart failure. Frostell et al. [18] have shown that during hypoxia in healthy volunteers, the dilatory effect of 40 ppm inhaled NO on the pulmonary artery pressure was a rapid onset with complete reversal of pulmonary hypertension within the first minute of breathing NO. In their study, calculation of the stroke work index for the right and left ventricles showed the ability of inhaled NO to reduce RV work selectively during hypoxia. Improvement in the PaO(2) could be made from therapies aimed at reducing pulmonary blood flow in shunting areas while increasing the flow in normally ventilated areas. The maintenance of a gradient of vascular resistance between ventilated regions receiving NO and regions where perfusion is reduced by hypoxic vasoconstriction would be particularly advantageous during the early stages of ARDS. This would be particularly true in the presence of situations characterized by a reduced or abolished hypoxic vasoconstriction response, such as pulmonary infection, septicemia, direct lung trauma, and septic shock. [19] In addition, endogenous release of NO can also modulate hypoxic vasoconstriction. [20] Marshall et al. [21] have suggested that a positive oxygen content change is only seen with NO when some constriction in addition to hypoxic pulmonary vasoconstriction is present in small arteries or veins or both. Therefore, the gain in PaO(2) observed with NO should be enhanced when combined with an infused vasoconstrictor. The vasoconstrictor used in combination with NO should mimic or enhance hypoxic vasoconstriction. This has been suggested by clinical studies in which inhaled NO was associated with a selective pulmonary vasoconstrictor, such as almitrine. [22,23] Almitrine increased the respiratory response to inhaled NO, [22,23] suggesting that enhancement of hypoxic pulmonary vasoconstriction in nonventilated lung areas could favor the diversion of blood flow toward better ventilated lung areas (where NO preferentially induced vasodilation). In nonventilated lung areas, mixed venous oxygen tension is primarily responsible for eliciting hypoxic pulmonary vasoconstriction. [24] When hypoxic pulmonary vasoconstriction is enhanced using almitrine, a decrease in intrapulmonary shunt occurs with an increase in oxygenation. In contrast, the decrease in hypoxic pulmonary vasoconstriction induced by extracorporeal blood flow in ARDS patients treated by venovenous extracorporeal lung assist results in an increase in intrapulmonary shunt. [25] The importance of the reinforcement of hypoxic pulmonary vasoconstriction in the improvement in oxygenation was supported by a recently published clinical study [26] that showed that using a nonselective vasoconstrictor (phenylephrine) in combination with inhaled NO resulted in a significant increase in PaO(2):FIO(2) ratio when compared with NO alone, but only in patients considered as phenylephrine responders (increase of the PaO(2):FIO(2) of at least 10 mmHg). The results of this latter study [26] suggested that inhaled NO can reverse phenylephrine-induced vasoconstriction in well-ventilated areas. Our results showed that in septic patients who received norepinephrine, inhaled NO provided a significant increase in the PaO(2):FIO(2) ratio. However, this increase was comparable to those observed in patients who did not receive norepinephrine. Using a logistic regression model, Mantkelow et al. [27] showed in a retrospective analysis of 88 ARDS patients that vasopressor requirement did not affect the response to inhaled NO. After controlling for other variables, these authors also found that the absence of septic shock was a positive predictor of the response to inhaled NO. This was not the case in the current study, in which patients with septic shock were compared with such patients without circulatory shock. Studying responders to inhaled NO, Mourgeon et al. [13] showed that although the dose response of MPAP and PVRI was not influenced by the presence of septic shock and the use of norepinephrine, the dose response of the PaO(2):FIO(2) ratio was modified by septic shock and norepinephrine. They observed a greater increase of the PaO(2):FIO(2) ratio and the absence of a plateau effect when patients received norepinephrine, whereas in patients without septic shock, they observed a plateau effect. When our results were expressed in terms of PaO(2):FIO(2) value, a difference between the two dose-response profiles was not apparent. In most patients, the inspiratory concentration of 5 ppm or less seems to be sufficient to improve oxygenation. [23,28] Even if the NO delivery and measurement system used in the current study does not allow for a precise evaluation of inspired NO concentration, the trends observed in the dose-responses are valid.
Bigatello et al. [28] showed that breathing 2-4 ppm NO appeared as effective as 20 ppm NO at improving arterial oxygenation and decreasing MPAP. Puybasset et al. [29] showed that therapeutic concentrations of NO were in the range of 0.1 to 2 ppm for patients who did not receive norepinephrine. Such low inspired NO doses should minimize any possible toxicity caused by NO inhalation. Bigatello et al. [28] and Puybasset et al. [30] found that the baseline level of pulmonary vascular resistance is the main determinant of the NO-induced pulmonary vascular effects. Our results confirm these previous studies. We did not find any correlation between the NO-induced decrease in MPAP and baseline MPAP. This absence of correlation between the decrease in pulmonary arterial pressure and improvement of oxygenation status was also noted by Sprague et al., [20] who showed that a significant intrapulmonary redistribution of blood flow away from hypoxic alveoli can occur in the absence of any change in pulmonary arterial pressure.
The interactions between norepinephrine and NO have been experimentally explored. Using NG-monomethyl-L-arginine, Julou-Schaeffer et al. [31] showed that this specific inhibitor of NO formation increased the sensitivity to norepinephrine, in control aortic rings, only when a functional endothelium was present. In an experimental model of hemorrhagic shock, Thiemermann et al. [32] showed that the vascular hyporeactivity to vasoconstrictor agents (including norepinephrine) is mediated by NO, showing the potential negative effect of NO on norepinephrine-induced vasoconstriction. Finally, in an experimental model, Pilati et al. [33] showed that the release of NO helps to maintain RV output during the release of norepinephrine induced by the massive sympathetic nervous system activity.
The RV dysfunction occurs even in the presence of a normal or high cardiac output, suggesting that the RV may be more susceptible than the left ventricle to the hemodynamic changes of sepsis. The inability of the RV to adequately increase its work output if its afterload is increased (such as by using a vasoconstrictor agent), as reflected by pulmonary arterial hypertension, is relevant in severe postseptic ARDS. Norepinephrine-induced pulmonary hypertension represents an additional increase in RV afterload that could precipitate RV failure. Martin et al. [11] showed that the administration of norepinephrine in patients with septic shock induced a significant increase in PVRI without a further deterioration of RV performance with no change in the RV end-diastolic ejection fraction. In the current study, the infusion of norepinephrine did not induce significant changes in RV end-diastolic ejection fraction in ARDS patients who received norepinephrine. This lack of deterioration of RV function could be explained by a positive inotropic effect of norepinephrine, the correction of systemic hypotension, which improved the right coronary perfusion pressure, or both.
The current study shows that the addition of inhaled NO to norepinephrine completely reverses norepinephrine-induced pulmonary vasoconstriction. In the absence of a change of intrathoracic pressure, the decrease in both MPAP and PVRI during NO inhalation suggests that RV afterload may decrease with NO inhalation, which probably explains the increase in RVEF. Because the increase in RVEF was accompanied by decreased RV end-systolic volume indices at a constant cardiac index during NO inhalation, these changes reflect the fact that the RV is working on another part of its pressure-volume loop, indicating a normal physiologic response of the RV in the presence of different loading conditions. Our results are comparable to those of Rossaint et al., [34] who reported that inhaled NO induced a decrease in pulmonary artery pressure associated with an increased RVEF, a decreased RV end-diastolic index and a decreased RV end-systolic volume index while cardiac index did not change significantly.
In conclusion, this study shows that patients with ARDS and sepsis who require a vasoactive drug such as norepinephrine seem to respond to inhaled NO in a manner similar to those who do not require norepinephrine.
The authors thank the nurses of the Sainte-Marguerite Hospital polyvalent intensive care unit for their support in conducting this study.
REFERENCES
Pepke-Zaba J, Higenbottam TW, Dinh-Xuan AT, Stone D, Walwork J: Inhaled nitric oxide as a cause of selective pulmonary vasodilation in pulmonary vasodilation in pulmonary hypertension. Lancet 1991; 338:1173-4
Rossaint R, Falke KJ, Lopez F, Slama K, Pison U, Zapol WM: Inhaled nitric oxide for the adult respiratory distress syndrome. N Engl J Med 1993; 328:399-405
Zapol WM, Snider MT: Pulmonary hypertension in severe acute respiratory failure. N Engl J Med 1977; 296:476-80
Tomashefski JFJ, Davies P, Boggies C, Greene R, Zapol WM, Reid LM: The pulmonary vascular lesions of the adult respiratory distress syndrome. Am J Pathol 1983; 112:112-26
Sibbald WJ, Driedger AA, Myers ML, Short AI, Wells GA: Biventricular function in the adult respiratory distress syndrome. Chest 1983; 84:126-34
Brunet F, Dhainaut JF, Devaux JY, Huyghebaert MF, Villemant D, Monsallier JF: Right ventricular performance in patients with acute respiratory failure. Intensive Care Med 1988; 14 suppl 2:474-7
Desjars P, Pinaud M, Potel G, Tasseau F, Touze MD: A reappraisal of norepinephrine therapy in human septic shock. Crit Care Med 1987; 15:134-7
Martin C, Papazian L, Saux P, Perrin G, Gouin F: Dopamine or norepinephrine in the treatment of hyperdynamic septic shock. Chest 1993; 103:1826-31
Sibbald WJ, Driedger A: Right ventricular function in acute disease states: Pathophysiologic considerations. Crit Care Med 1983; 11:339-45
Vincent JL, Reuse C, Frank N, Contempre B, Kahn RJ: Right ventricular dysfunction in septic shock: Assessment by measurements of right ventricular ejection fraction using thermodilution technique. Acta Anesthesiol Scand 1989; 33:34-8
Martin C, Perrin G, Saux P, Papazian L, Gouin F: Effects of norepinephrine on right ventricular function in septic shock patients. Intensive Care Med 1994; 20:444-7
Krafft P, Fridrich P, Fitzgerald RD, Koe D, Steltzer H: Effectiveness of nitric oxide inhalation in septic ARDS. Chest 1996; 109:486-93
Mourgeon E, Puybasset L, Law-Koune JD, Lu Q, Abdennour L, Gallart L, Malassine P, Umamaheswara Rao GS, Cluzel P, Bennani A, Coriat P, Rouby JJ: Inhaled nitric oxide in acute respiratory distress syndrome with and without septic shock requiring norepinephrine administration: A dose-response study. Crit Care 1997; 1:25-39
Bernard GR, Artigas A, Brigham KL, Carlet J, Falke K, Hudson L, Lamy M, Legall JR, Morris A, Spragg R, and the Consensus Committee: The American-European consensus conference on ARDS. Am J Respir Crit Care Med 1994; 149:818-24
Members of the American College of Chest Physicians/Society of Critical Care Medicine. American College of Chest Physicians/Society of Critical Care Medicine Consensus Conference: Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. Crit Care Med 1992; 20:864-74
Dhainaut JF, Brunet F, Monsallier JF, Villemant D, Devaux JY, Konno M, De Gournay JM, Armaganidis K, Iotti G, Huyghebaert MF, Lanore JJ: Bedside evaluation of right ventricular performance using a rapid computerized thermodilution method. Crit Care Med 1987; 15:148-52
Vincent JL, Thirion M, Brimioulle S, Lejeune P, Kahn RJ: Thermodilution measurement of right ventricular ejection fraction with a modified pulmonary artery catheter. Intensive Care Med 1986; 12:33-8
Frostell CG, Blomqvist H, Hedenstierna G, Lundberg J, Zapol WM: Inhaled nitric oxide selectively reverses human hypoxic pulmonary vasoconstriction without causing systemic vasodilation. Anesthesiology 1993; 78:427-35
Reeves J, Grover R: Blockade of acute pulmonary hypertension by endotoxin. J Appl Physiol 1974; 36:328-32
Sprague R, Thiemermann C, Vane JR: Endogenous endothelium-derived relaxing factor opposes hypoxic pulmonary vasoconstriction and supports blood flow to hypoxic alveoli in anesthetized rabbits. Proc Natl Acad Sci U S A 1992; 89:8711-5
Marshall BE, Hanson CW, Frasch F, Marshall C: Role of hypoxic pulmonary vasoconstriction in pulmonary gas exchange and blood flow distribution. 2. Pathophysiology. Intensive Care Med 1994; 22:379-89
Wysocki M, Roupie E, Langeron O, Liu N, Herman B, Lemaire F, Brochard L: Additive effect on gas exchange of inhaled nitric oxide and intravenous almitrine bismesylate in the adult respiratory distress syndrome. Intensive Care Med 1994; 20:254-9
Lu Q, Mourgeon E, Law-Koune JD, Roche S, Vezinet C, Abdennour L, Vicaut E, Puybasset L, Diaby M, Coriat P, Rouby JJ: Dose-response curves of inhaled nitric oxide with and without intravenous almitrine in nitric oxide-responding patients with acute respiratory distress syndrome. Anesthesiology 1995; 83:929-43
Marshall C, Marshall B: Site and sensitivity for stimulation of hypoxic pulmonary vasoconstriction. J Appl Physiol 1983; 55:711-6
Benzing A, Mols G, Brieschal T, Geiger K: Hypoxic pulmonary vasoconstriction in nonventilated lung areas contributes to differences in hemodynamic and gas exchange responses to inhalation of nitric oxide. Anesthesiology 1997; 86:1254-61
Doering EB, Hanson CW, Reily DJ, Marshall C, Marshall BE: Improvement in oxygenation by phenylephrine and nitric oxide in patients with adult respiratory distress syndrome. Anesthesiology 1997; 87:18-25
Mantkelow C, Bigatello LM, Hess D? Hurford WE: Physiologic determinants of the response to inhaled nitric oxide in patients with acute respiratory distress syndrome. Anesthesiology 1997; 87:297-307
Bigatello LM, Hurford WE, Kacmarek RM, Roberts JD, Zapol WM: Prolonged inhalation of low concentrations of nitric oxide in patients with severe adult respiratory distress syndrome. Anesthesiology 1994; 80:761-70
Puybasset L, Rouby JJ, Mourgeon E, Stewart TE, Cluzel P, Arthaud M, Poete P, Bodin L, Korinek AM, Viars P: Inhaled nitric oxide in acute respiratory failure: Dose-response curves. Intensive Care Med 1994; 20:319-27
Puybasset L, Rouby JJ, Mourgeon E, Cluzel P, Souhil Z, Law-Koune JD, Stewart T, Devilliers C, Lu Q, Roche S, Kalfon P, Vicaut E, Viars P: Factors influencing cardiopulmonary effects of inhaled nitric oxide in acute respiratory failure. Am J Respir Crit Care Med 1995; 152:318-28
Julou-Schaeffer G, Gray GA, Fleming I, Schott C, Parratt JR, Stoclet JC: Loss of vascular responsiveness induced by endotoxin involves L-arginine pathway. Am J Physiol 1990; 259:H1038-43
Thiemermann C, Szabo C, Mitchell JA, Vane JR: Vascular hyporeactivity to vasoconstrictor agents and hemodynamic decompensation in hemorrhagic shock is mediated by nitric oxide. Proc Natl Acad Sci U S A 1993; 90:267-71
Pilati C, Maron MB, Bosso FJ: Role of EDRF in the cardiopulmonary dysfunction produced by massive sympathetic activation. J Appl Physiol 1995; 78:1642-50
Rossaint R, Slama K, Steudel W, Gerlach H, Pappert D, Veit S, Falke K: Effects of inhaled nitric oxide on right ventricular function in severe acute respiratory distress syndrome. Intensive Care Med 1995; 21:197-203
Figure 1. Dose-response analysis of inhaled nitric oxide in patients with (group 2: 12 patients; open bars) and without (group 1: 15 patients; hatched bars) norepinephrine (NE). For the median ratio of oxygen pressure in arterial blood to the fractional concentration of oxygen in inspired gas (25, 50, and 75 percentiles), the largest and smallest values that are not outliers are reported. Outliers (cases with values between 1.5 and 3 box-lengths from the upper or lower edge of the box) are presented as open circles. Extremes (cases with values more than 3 box-lengths from the upper or lower edge of the box) are represented by a cross.
Figure 1. Dose-response analysis of inhaled nitric oxide in patients with (group 2: 12 patients; open bars) and without (group 1: 15 patients; hatched bars) norepinephrine (NE). For the median ratio of oxygen pressure in arterial blood to the fractional concentration of oxygen in inspired gas (25, 50, and 75 percentiles), the largest and smallest values that are not outliers are reported. Outliers (cases with values between 1.5 and 3 box-lengths from the upper or lower edge of the box) are presented as open circles. Extremes (cases with values more than 3 box-lengths from the upper or lower edge of the box) are represented by a cross.
Figure 1. Dose-response analysis of inhaled nitric oxide in patients with (group 2: 12 patients; open bars) and without (group 1: 15 patients; hatched bars) norepinephrine (NE). For the median ratio of oxygen pressure in arterial blood to the fractional concentration of oxygen in inspired gas (25, 50, and 75 percentiles), the largest and smallest values that are not outliers are reported. Outliers (cases with values between 1.5 and 3 box-lengths from the upper or lower edge of the box) are presented as open circles. Extremes (cases with values more than 3 box-lengths from the upper or lower edge of the box) are represented by a cross.
×
Figure 2. The effect of nitric oxide on mean pulmonary arterial pressure (mean +/− SD) in patients receiving norepinephrine (n = 12; closed symbols) and in those who did not receive norepinephrine (n = 15; open symbols).
Figure 2. The effect of nitric oxide on mean pulmonary arterial pressure (mean +/− SD) in patients receiving norepinephrine (n = 12; closed symbols) and in those who did not receive norepinephrine (n = 15; open symbols).
Figure 2. The effect of nitric oxide on mean pulmonary arterial pressure (mean +/− SD) in patients receiving norepinephrine (n = 12; closed symbols) and in those who did not receive norepinephrine (n = 15; open symbols).
×
Table 1. Characteristics of the Population
Image not available
Table 1. Characteristics of the Population
×
Table 2. Hemodynamic and Respiratory Changes Induced by Norepinephrine
Image not available
Table 2. Hemodynamic and Respiratory Changes Induced by Norepinephrine
×
Table 3. Dose-Response Effects of Nitric Oxide on Gas Exchange
Image not available
Table 3. Dose-Response Effects of Nitric Oxide on Gas Exchange
×
Table 4. Dose-Response Effects of Nitric Oxide on Circulatory Parameters
Image not available
Table 4. Dose-Response Effects of Nitric Oxide on Circulatory Parameters
×
Table 5. Dose-Response Effects of Nitric Oxide on Derived Factors
Image not available
Table 5. Dose-Response Effects of Nitric Oxide on Derived Factors
×